Год производства: 2006
MODEL Aquilion 64
X-RAY TUBE
X-RAY TUBE ANODE
Heat storage, hu (X-ray tube anode) 7500000
Heat dissipation rate, hu/min (X-RAY TUBE) 1, 386, 000 max
Tube cooling (X-ray tube anode) Oil/air
Tube focal spot, mm (X-ray tube anode) 1. 6 x 1. 4, 0. 9 x 0. 8 (IEC standard)
POWER NEEDED 200 VAC, 50/60 Hz, 3-phase
Type (CONFIGURATION) Multislic ehelical
# of slices (X-ray tube anode) 64
TABLE FEATURES
Range of movement
Vertical, cm (Range of movement) 31-94. 4
Longitudinal, cm (Range of movement) 219
Scanning range, cm (Range of movement) 180
Max. patient weight, (precision), kg (Range of movement) 205 (±0. 25 mm)
Image storage
Hd capacity, gb (IMAGE STORAGE) 180, 720 raw data, max 3, 600 rotations
No. online images (IMAGE STORAGE) 160000
Archive (IMAGE STORAGE) 9. 4 GB DVD-RAM
GENERATOR
Output, kw (X-RAY GENERATORS) 60
Kvp range (GENERATOR) 80, 100, 120, 135
Ma range (IMAGING SYSTEM) 1010-50 in 5 mA steps
DICOM 3. 0 COMPATIBLE (POWER NEEDED, VAC) Yes
PERFORMANCE
Minimum interscan time, sec (PERFORMANCE) 0
Dynamic scan pace (PERFORMANCE) 200 scans/100 sec
High-contrast spatial resolution 0% mtf, lp/cm (PERFORMANCE) 18
50% mtf, lp/cm (PERFORMANCE) 8
Low-contrast resolution, mm at % at =4 rads (PERFORMANCE) 2 at 0. 3%
Sound, % at = 2. 5 rads (PERFORMANCE) 0. 5
DISPLAY
MONITOR 18" LCD color x 2
Matrixes, pixels (DISPLAY) 1280 x 1024
Range of ct numbers (DISPLAY) -1, 536 to +8, 191
Image enlarging scale (DISPLAY) Up to 20x
Max # slices displayed simultaneously (DISPLAY) 16
HELICAL SCANNING (DISPLAY) Yes
Max scan time, sec (DISPLAY) 100
Max scan volume, cm (DISPLAY) 175
Spatial resolution, lp/cm (DISPLAY) 18 at 0% MTF
Pitch (DISPLAY) 0. 8-96 mm/sec couch-top speed
Reconstruction time per image, sec (DISPLAY) 0. 1
FLOOR SPACE NEEDED
Size, m2 (FLOOR SPACE NEEDED) 27 (25 short couch)
SCORING OF CORONARY ARTERY CALCIFICATION (IMAGE STORAGE) Optional
IMAGE PROCESSING (MAXIMUM DISPLAY)
Cpu (NETWORK/DATABASE) 32-bit processor x 2
Scan fovs, cm (IMAGE PROCESSING) 18, 24, 32, 40, 50
Image reconstruction matrixes (IMAGE PROCESSING) 512 x 512
Reconstruction time
Per slice, sec (Reconstruction time) 0. 1
For localization scan, sec (Reconstruction time) Real time
GANTRY
Geometry (GANTRY) Rotate-rotate, slip ring, multislice
DETECTOR (SCATTERED LIGHT) Solid-state
Rows (GANTRY) 64
Elements/row (GANTRY) 64 x 896
# detection channels (GANTRY) 64 x 896
Rotation times, sec 360 (GANTRY) 0. 5, 0. 75, 1, 1. 5, 2, 3; optional 0. 4
Partial (GANTRY) 0. 32; optional 0. 25
Slice thickness, mm (GANTRY) 0. 5 x 64: 1 x 32; 2 x 16; 0. 5, 1, 2, 3, 4, 6, 8 (all x 4)
X-ray fan beam angle, ?° (GANTRY) 49. 2
Gantry angle deg (GANTRY) ±30
Gantry size, hxwxd, cm (GANTRY) 195 x 233 x 96
Gantry weight, kg (GANTRY) 1750
Gantry opening, cm (GANTRY) 72
Scan localizer (GANTRY) Laser
OTHER ATTRIBUTES (Interference compensation) Cerebral blood-flow analysis syatem; quantitive bone mineral analysis; CT fluoro; full DICOM featue set; pediatric scanning; SureStart contrast tracking; SureScan real-time imaging; volume rendered 3-D; ECG gating; cardiac scoring; cardiac function analys
FDA CLEARANCE (Interference compensation) Yes
CE MARK (MDD) (Interference compensation) Yes
MARKETING REGION (Interference compensation) Worldwide
Our specifications
Год производства: 2006
Serial number: HCA06Z2451
Tube model: MSC7078DREV2
Serial number: 92421-R4 (replaced 25/08/2014)
Tube scan seconds: 362. 446
Gantry count: 2. 129. 181
Software version: V5. 10*R007
Including: Mallinckrodt Optivantage DH contrast injector BuyReklama.ru
Цена: | 6800000,00 рублей |